Interphase-tech RAS Communications Controller 5536 Manual de usuario Pagina 53

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 244
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 52
Chapter 3: Connecting to the Line
5536 PRI RAS Communications Controller Users Guide 33
E1 Link Requirements
If the board connects to the E1 line, the board and NT1 must
be configured with several common parameters to
interoperate. The board’s E1 parameters are in accordance
with the IUT-T I 431 recommendation, as follows:
• Line coding: HDB3, according to IUT-T G.703
• Frame format: according to IUT-T G.704
CRC4 to Non-CRC4 operation: according to
IUT-T G.706 An.B
Line I/O impedance: 120 Ohm ± 5%
Vista de pagina 52
1 2 ... 48 49 50 51 52 53 54 55 56 57 58 ... 243 244

Comentarios a estos manuales

Sin comentarios